The third wire is for the interconnect, not a ground. The alarm you have may not match exactly the image shown. Are smoke detectors wired in series or parallel? If any unit in the series senses smoke, all units will alarm. Michigan. Check the manufacturers guidance on each alarm for instructions on where the alarm should be placed. Can someone please verify that it is 9 vdc on the brk9120's? If any unit in the series does not alarm, TURN OFF POWER and recheck connections. These alarms sound simultaneously, on all levels of your home, when a single unit detects smoke or gas. 4.1 First Alert SCO500B Wireless Interconnected Photoelectric Smoke and Carbon Monoxide Combo Alarm with Voice and Location. How can this new ban on drag possibly be considered constitutional? More reliable hard-wired units also have battery back-up for added safety, in case of power outages. You can't be sure what's going on in the electronics, and whether an issue may develop in the future. Hard-wired smoke detectors can be interconnected between units via an orange wire within each unit. When power is interrupted, only the AC/DC units in the series will continue to send and receive signals. All the units are wired to a 120-volt household electrical circuit and each have a battery backup. Users are further shielded from late night battery chirps by the units Ambient Light Sensing feature, which establishes a day/night cycle and prevents alarm chirping in dark conditions. THIS ADAPTER CAN ONL Y BE USED WHEN REPLACING FIRST. You can replace a smoke detector with a combination smoke/CO unit. Thanks for contributing an answer to Home Improvement Stack Exchange! SA521CN-3ST Interconnected Smoke Alarm with Hardwire Adapter Included, Requires a pro for pricing, installation and warranty. Remove the power connector from the new alarm's packaging. Why does my hardwired smoke alarm go off for no reason? Easy Installation: Universal mounting bracket and plug-in power connector for hassle-free installation. In an older home, for instance, its not always possible to wire new cabling throughout most of the rooms in the house to set up a complete fire alarm system. If you need to remove the power connector, insert a flat screwdriver blade between the power connector and the security tab inside the power input block. Whats the meaning of interconnect? The smoke alarms must be installed and kept in a clean environment to work properly, as dust and grime can accumulate inside and alter how they operate. Please refer to users manual or contact BRK Consumer Affairs for specific details. Newer models offer more features. The smoke alarm interconnect is a CMOS I/O pin from the IC, which typically runs off 9VDC from a battery and/or mains capacitive voltage divider. Strip off about 1/2 (12 mm) of the plastic coating on the orange wire on the power connector. The alarm interconnect shall be supervised, where an audible and visual indication is given if the alarm loses connection to other units in the network. The same fuse or circuit breaker in the home powers all interconnected units. If it is not used it will keep the wiring from possibly shorting out. Improper Alarm Installation. Mar 1, 2018. lighterup said: If all your doing is the alarm interconnect ( red /orange wire on. It's pretty low current around 4mA with a weak battery, to 16mA typical. 7. 5. If it is not used it will keep the wiring from possibly shorting out. problems contact webmaster@doityourself.com. Restoring power before installation is complete may result in serious electrical shock, injury or death. After an Alarm (If Latching Feature is present): On Initiating Alarm(s) Green LED(s) On for 2 seconds/Off for 2 seconds, On All Other Alarms Green LED(s) On, Red LED(s) is Off. Some smoke detectors have an interconnect wire (orange wire) used for connecting smoke detectors together. The third wire, in your case the yellow one, in my case the red one, is how the smoke detectors are interconnected. What is the best interlinked smoke alarms? the 14-2 to interconnect the alarm . Contact Us When one alarm sounds, all connected alarms in the system will sound simultaneously. It ships in the box without the wire pre-stripped. Why are physically impossible and logically impossible concepts considered separate in terms of probability? Probably 9v, since that's the backup battery voltage on the smoke alarm. The One Link Smart Smoke Detector is the new smart smoke detector the market and will interconnect with most existing hardwired interconnected smoke detectors and with other One Link Smart Smoke Detectors. Repeat for each unit you are interconnecting. In the instructions for many smoke detectors, specific brands / models are indicated are compatible to interconnect. Below are some things to consider when trying to figure out what is the interconnect wire on a smoke detector. Remove the alarm and use a non-contact voltage detector to check the wires to make sure the power is off. First Alert Smart Strobe Lights include a wide compatibility range and can be interconnected with First Alert and BRK Smoke, CO, Smoke/CO Combination and Heat alarms (up to 18 detectors, 12 can be smoke alarms). QLD Smoke alarm legislation requirements With this year's horrific bushfire season still fresh in our memories, ensuring your home is compliant and set up to give your family the best possible chance of survival in a fire situation should be a top priority. How do you turn off an interconnected smoke detector? Nuetral (White) AC Wire 6. Nests way 6-9 smoke detectors, 6-8 login, 6-8 ip address. What is interconnect? No battery replacement required over the 10 year life of the. It supplies the unit with AC power. Each has its particular advantages for specific installations or usage. How can I tell if my smoke alarms are interconnected? How to handle a hobby that makes income in US. see less I think very few here understand the question. 2. Existing networks of interconnected alarms can be expanded with use of a single AC Wire-Free Alarm and additional compatible DC Wire-Free alarms. Connect the orange wire on the power connector to the interconnect wire in the junction box. Now I'm not so sure :) however empirical evidence from bunch of different alarms going off at once suggests that they operate just fine. If an issue does prevent the device from working properly, it could be undiscovered until the worst possible time. Even if you connect them, and test them, and they seem to work - that's not a substitute for the kind of testing the manufacturer or test lab would do. If you buy an AC-powered smoke detector today, it will have three wires black, white and red. (I'd assume the manufacturer tests their product with those listed compatible, and UL verifies.) Carefully tuck the wires through the mounting plate, then secure the smoke detector to the mounting plate, following the manufacturer's directions. Otherwise all households will experience unwanted alarms when you test any unit in the series. Most alarms can handle about a dozen units intercommunicating on the same red wire. Yes. Single Station Alarms: Test each Smoke Alarm. Under normal operation, the Green power indicator light will shine continuously. Additional benefits and features are available when used in conjunction with the Kidde RemoteLync Bridge, which connects P4010 Wire-Free alarms via your homes Wi-Fi to your smart device. If one detects a problem they all sound the alarm. Pack . I've read elsewhere of problems with interchangeability, even within the same brand. The unit shall have audible methods for warning of smoke or fire danger: a piezoelectric horn, rated at 85 decibels at 10 feet, and a voice warning. Google Home is a registered trademark of Google LLC. Pull-out battery drawer 8. 407 60K views 4 years ago What is the red wire used for on smoke detector? WIRING A SMOKE DETECTOR Safely For Beginners. But the corresponding hardwire BRK alarms get terrible reviews (see Passive-Aggressive smoke detectors for the type of problem). Is it OK to rinse with hydrogen peroxide everyday? Bug Screen -Protects alarm from insect ingression, Flashing LED Status Ring allows easy identification of current state of alarm. Also question is,how do i know if my smoke detectors are interconnected? Also know,what is the orange interconnect wire on a smoke detector? Free shipping for many products! Why does my smoke detector have 3 wires? View complete answer on home.howstuffworks.com, View complete answer on support.firstalert.com, View complete answer on community.screwfix.com, View complete answer on onehoursmarthome.com, View complete answer on diy.stackexchange.com, View complete answer on familyhandyman.com, View complete answer on uk.prysmiangroup.com, View complete answer on wirechiefelectric.com. Once you hear the unit chirp, release the test button. If you buy an AC-powered smoke detector today, it will have three wires -- black, white and red. Does it make sense to try mounting the jigsaw onto the table? This unit is designed to be compatible with all current model First Alert and BRK alarms. The units must be kept free of paint, stickers, decorations, or anything else that could alter their performance. It only takes a minute to sign up. Quabbin Multipair Control & Sound Interconnect, AWM 2464 - 22 A the room and alarm type) do they do that over the interconnect wire also? Yann Wehrling, vice-prsident de la rgion le-de-France, charg de la Transition cologique, et Patrice . Find many great new & used options and get the best deals for Kidde P4010DCSCO-W Wire-Free Interconnect Combination CO Smoke Alarm at the best online prices at eBay! To remove the mounting bracket from the Smoke Alarm base, hold the Smoke Alarm base firmly and twist the mounting bracket counterclockwise. The maximum distance between wireless interconnect models is greater than 300 feet in open air. Quote from Youtube video: So to join another alarm to it what you're gonna do is you're gonna hold this down twice. Remove the mounting bracket from the base, and attach it to the junction box. That 9 volt battery is also there to operate the sensors and sound the alarm (it's not a horn, it's a piezo electric device) if the power goes out. ALERT AND BRK MODELS; SA4121B, 4120, 4919, 5919, AND 86RAC WITH PLUG-IN CONNECTOR, MANUF ACTURED. Can airtags be tracked from an iMac desktop, with no iPhone? Single Button Test/Silence eliminates confusion. The vendor instructions of course tell you to use only matching alarms. I'd like to know if I can purchase higher quality units and still interconnect them. Any recommendations for smoke detectors with wireless remote alarms? This is for safety reasons. If interconnected it is best if they are all the same brand. And let go. The other Alarms sounding only tests the interconnect signal between Alarms. These alarms sound simultaneously, on all levels of your home, when a single unit detects smoke or gas. In case of fire, the interconnection can save precious moments as the detector sounds the alarm simultaneously with all other alarms connected into it. An AC smoke alarm can be interconnected, meaning if a fire starts and an alarm goes off, all the alarms in the home will go off as well. What if anything does blue tape mean on a wire for a smoke alarm circuit? Create a personalized fire safety package, Combination Smoke & Carbon Monoxide Alarms, 1039830 Interconnected Smoke Alarm with Hardwire Adapter Included, INTERCONNECTED SMOKE ALARM WITH HARDWIRE ADAPTER INCLUDED, When one alarm is triggered, all connected alarms will sound, Integrated battery backup allows continuous detection during power outages, Hardwired smoke alarm can communicate wirelessly with other compatible alarms to create a fire alarm system (additional alarms sold separately), Advanced Features for More Complex Systems. "How do smoke detectors intercommunicate?" Quick-Connect Plug 1. How do you interconnect wireless smoke detectors? I'm guessing you want to use a relay on that interconnect. Browse other questions tagged, Start here for a quick overview of the site, Detailed answers to any questions you might have, Discuss the workings and policies of this site. Quote from the video: Any alarm that detects a 9-volt signal on the red wire will begin sounding its alarm immediately. Its a good idea to have at least one light or receptacle-on the same circuit, to alert the homeowners in case the circuit breaker ever trips. Asking for help, clarification, or responding to other answers. Is there any difference in the type of wiring in common household? There's a single test-and-silence button, and the backup nine-volt battery is. suggestions. Do not connect it to any other type of alarm or auxillary device. What is the orange wire on a smoke detector? Find an authorized professional near you to complete your installation. Take the first step toward protecting your home & family. Additional information such as battery life and sensor health status are available from each assigned room location. The orange wire is used for interconnect. ? Why? Please copy/paste the following text to properly cite this HowStuffWorks.com article: An electrician can interconnect smoke detectors using a three-way switch, which contains black, red and white wires. It's a beautiful peninsula, I've looked. Free shipping. About an argument in Famine, Affluence and Morality. Although it's possible to hardwire your own interconnected smoke alarms, there are many complications involved and all wiring must conform to electrical codes. The voice warning feature accompanies the 85dB tone during an alarm event, and helps reduce confusion with verbal announcements such as Replace alarm at end of alarm life, and Hush mode activated when a nuisance alarm is silenced. Offer valid thru Wire Nut 5. Equipped with battery backup, this smoke and fire alarm allows for protection during power outages. How to notate a grace note at the start of a bar with lilypond? If you are interconnecting more than one Smoke Alarm, you MUST read Special Requirements For Interconnected Smoke Alarms below before you begin installation. Also worth mentioning is that the hard-wired system can be connected directly to alert the fire station in case of fire. What is the correct way to screw wall and ceiling drywalls? Where Is The Reset Button On A Smoke Detector, What Is The Best 9 Volt Battery For A Smoke Detector, How To Smoke Inside With A Smoke Detector, What Does Push To Hush Mean On A Smoke Detector, Some Critical Questions to Consider While Purchasing a Grill Cover, Ten Tips for Hosting a Summer Party at Home, Fatty In Trouble 2: Bull Ride for Android App, KicksandKaviar Dedicated To The Urban Camper kicks, sneakers, NOISEMAKERS: Live Hip Hop Interview Series, Know Mo Mobilizing Knowledge about Addiction & Mental Health in Alberta, Generalized Problematic Internet Use Scale (GPIUS), New report about Edmontons street-involved youth, Back to the Basics: Word of Mouth Marketing, Aacua By Maaman Review and Giveaway ** Closed**, The Humiliations of Motherhood: Enough to Scare the Crap Out of Anyone (Quite Literally), How to treat depression safely while breastfeeding: An interview with Dr. Kathleen Kendall-Tackett. SEARCH: HOW TO INSTALL BRK HARDWIRED SMOKE, CARBON MONOXIDE AND HEAT ALARMS. Free shipping for many products! https://www.brooks.com.au/home-smoke-alarms/battery-powered/wall-mount-test-locate-silence-memory-control-eib450/, We've added a "Necessary cookies only" option to the cookie consent popup, Integrating hard-wired smoke detectors with fire sprinkler waterflow sensing. Failure to turn off the power before installation may result in serious electrical shock, injury or death. Hardwired systems often include a battery backup component. We welcome your comments and If I have a Zoned HVAC system, should there be more than one filter to change? Proper smoke alarm installation can prevent your system from going off when it shouldn't. The interconnect wire, which is usually colored orange, is for connecting smoke alarms together. Can battery operated smoke alarms be interconnected? 4.7 average based on 3 product ratings. Another thing I think I had to do was make the interface fail safe, IOW, if the interface failed, even catastrophically, it was required that such a failure not impede the operation of the alarms. This type of wire is commonly available at Hardware and Electrical Supply stores. Beside above,what is interconnect on smoke detector? 2. 1/1/01 To determine which Smoke Alarm initiated an alarm: On Initiating Alarm(s) Red LED(s) flashes (flash) rapidly. This video teaches you how to wire and interconnect smoke detectors. Does Counterspell prevent from any further spells being cast on a given turn? How does a contractor determine the water performance rating needed for a sliding glass door? Contact Us | 10-Year Sealed Lithium Battery Eliminates late night battery chirp! The orange interconnect wire should NEVER be connected to earth; it should only be used to interconnect other smoke alarms or compatible devices. If you are only installing one Smoke Alarm, restore power to the junction box. New alarms are inexpensive. The weakness of these systems is obviously that they rely solely on batteries for power, while hardwired systems are physically connected to an energy source, allowing them to reliably alert all units. Wireless Interconnect: Can be linked with up to 18 units (12 Smoke, 6 CO/Heat/Relay) Smart Sensing Technology: Helps reduce nuisance alarms. Intelligent Wire-Free Alarms (6) Micro 10-Year Sealed Battery Smoke Alarm i1040 4.2 (96) Retail Price $19.99 Where to Buy Add to Compare Kidde Sealed Lithium Battery Power Smoke Alarm i9010 3.2 (76) Retail Price $31.47 Where to Buy Add to Compare Worry-Free Bedroom Sealed Lithium Battery Power Smoke Alarm P3010B 1.2 (21) Retail Price $33.97 In addition, if you have a home with more than one floor, its important for the smoke alarms to be wired in parallel so if one goes off in the basement, every alarm will sound throughout the home. Connect the white wire on the power connector to the neutral wire in the junction box. Stack Exchange network consists of 181 Q&A communities including Stack Overflow, the largest, most trusted online community for developers to learn, share their knowledge, and build their careers. All rights reserved. What is the difference between 2wire and 4 wire smoke detectors? You must test each Alarm individually to check if the Alarm is functioning properly. Optipath 360 Technology the smoke sensor. 3. Correcting this solved the problem. Making statements based on opinion; back them up with references or personal experience. Hardwired smoke alarms can be interconnected. Do smoke detectors need to be daisy chained? Check to make sure the power is off with your voltage tester. This is for safety reasons. On some models, the batteries must be replaced at least once every six months or once a year, depending on the model, so it is best to consult the installation manual to verify which one applies. : to be or become mutually connected. There are a few different types of smoke detectors available, but they can generally be classified as either AC smoke alarms (also known as interconnected or hardwired smoke detectors), or battery operated units. The First Alert Interconnected Smoke Alarm with Hardwire Adapter Included makes it easy to begin creating a safety network of detection. It is used for interconnect only. Also know,what is the orange interconnect wire on a smoke detector? The units must be dusted and vacuumed regularly. Thread the wires through the mounting bracket. This is for safety reasons. What you will need for fixing them Equipment and Tools: Tape measure 6- foot stair ladder Pencil Drywall saw Stud finder Cordless drill Cable ripper voltage tester Fish tape Wire stripper Materials: Old- worked electrical boxes Hardwired smoke detectors UL- approved wire connectors 3-wire cable 2-wire cable. Leading authorities recommend that both ionization and photoelectric smoke alarms be installed to help ensure maximum detection of the various types of fires that can occur within the home. What is the interconnect wire on a smoke detector? Black accepts 120 volts AC, white is neutral, and red is the intercommunication wire. Then screw the plate into the ceiling/wall with the two screws that you removed earlier. : to connect with one another. In these cases, a battery-operated system not requiring the use of terminal boxes or wiring may be more appropriate, and will still remain in operation the event of a power outage, Most municipality codes prevents the use of, battery-operated units in new construction, requiring hardwired alarms in all new residences, , the wires from the alarm are shown connected inside the junction box in the ceiling. We highly recommend installing interconnected smoke alarms, but call a professional. Can a wireless smoke detector be interconnected with a hard-wired one? For a better experience, please enable JavaScript in your browser before proceeding. Can you interconnect different brands of smoke detectors? If one alarm goes off, the rest of the alarms will follow suit. AC powered Smoke Alarms will not operate. For example . Can I upgrade my hardwired smoke detector in apartment without triggering central alarm? Kidde i12040 120V AC Wire-In Smoke Alarm with Battery Backup and SmartHush-2pack. A hard-wired smoke alarm or carbon monoxide alarm is connected to other detectors throughout your home. As to having hardwired alarms on different circuits, not a good idea as it tends to cause RCDs to trip whenever interconnected alarms trigger and sound. A hard-wired smoke alarm or carbon monoxide alarm is connected to other detectors throughout your home. . A hardwired smoke alarm could go off because of a dead backup battery, power surges, improper installation, dust in the air or humidity. The total length of wire interconnecting the units should be less than 1000 feet (300 meters). Can you mix wired and wireless smoke detectors? 4.3 Kidde RF-SM-DC Smoke Alarm. The best answers are voted up and rise to the top, Not the answer you're looking for? I believe many use the same voltage on the interconnect, but still it is a code violation to interconnect them if it the combination is not specifically permitted in the instructions. Residential smoke alarms should be wired on a dedicated circuit. Equipped with an easy adapter plug, there is no need to rewire when installing the fire alarm. Quote from the video: This detector is designed to replace an existing hardwired 120-volt alarm so you can add up to 18 First Alert wireless interconnected alarms By connecting multiple wireless interconnected detectors, you can be alerted to danger on the other side of your house before the smoke from that area reaches you. The P4010DCS-W is a 10-year, sealed battery smoke alarm that features supervised wire-free interconnect capability and provides enhanced intelligibility for users. Smoke detectors should be tested monthly to ensure proper function. 4 Wireless Smoke Detectors that Communicate with each other. Is it acceptable to have detectors on different electrical circuits, connected only with an interconnect wire (will that cause the interconnect to be referenced to the wrong ground level?). Connect the red circuit wire (s) to the interconnect (traveler) wire from the smoke detector, usually marked as yellow. When construction is complete, remove cover. By Dave Rongey. Code requires that devices be used according to their listing, following the manufacturer's instructions. 5. Are you referring to the output on the interconnection conductor? Has 90% of ice around Antarctica disappeared in less than a decade? Is it not true the interconnect voltage is whatever the battery is currently putting out? All modern hardwired First Alert, Onelink, and BRK alarms use the same wiring technology, and can interconnect. I doubt that smoke alarms 'communicate' in any manner as simple as just supplying power to the horns. Like wired smoke detection systems, wireless smoke detectors are code compliant when they meet NFPA standards. The orange wire is used for interconnect. JavaScript is disabled. Hardwired interconnection uses the wiring in your home to link AC-powered alarms together. A maximum of 24 Kidde Safety devices may be interconnected in a multiple station arrangement. If one alarm goes off, the rest of the interconnected alarms will alert as well. For example, if you have 5 smoke detectors interconnected with one combo unit, only the combo smoke/CO unit will sound the CO alarm. If a human error was to cause someone to forget replacing a battery, the wireless system would become useless while the hard-wired would still be operating. But if you have AC-powered smoke detectors in your home and your home has been built in the last 10 years in the U.S., chances are they are wired together to intercommunicate. Press and hold the test button for at least 15 seconds. Thank you for signing up. It's a very simple and a very effective system. The basic installation of this Smoke Alarm is similar whether you want to install one Smoke Alarm, or interconnect more than one Smoke Alarm. A low-battery light and chirp will let you know when the AA batteries need to be replaced in the smoke detector. Find many great new & used options and get the best deals for 6 Lot NEW KIDDE FireX i12060 HARDWIRED SMOKE ALARM w Battery Backup interconnect at the best online prices at eBay! Not open for further replies. It will reset in eight minutes, given that the smoke and debris have dissipated. Press and hold the Test/Silence button until the unit alarms. Kidde P4010 Series Alarms contain 10-year tamper proof batteries that eliminate the need for battery replacement, and ends worry over unauthorized removal. A life-saving advantage of the interconnected systems installed in all the critical areas of the house is that each individual unit can triggers a general alarm throughout the entire home, no matter where the fire originated from, to warn all its residents of imminent danger. Never cross hot and neutral wires between Alarms. Press the hush/silencing button. If you have black, white, yellow, red and ground instead, you must have a conduit system. Interconnect Wire (Orange) 8. Make sure the Smoke Alarm is receiving AC power. All information is provided "AS IS." Detects smoke and carbon monoxide Interconnected system Battery backup for power outages Works with other Kidde bases What We Don't Like Expensive May need professional installation Having a hardwired smoke detector helps it integrate with other sensors to create a comprehensive home safety system. On. Free shipping for many products! Instead of your smoke alarms operating independently of one another, interconnected smoke alarms work as an interlinked system. They are now also using RF wireless interconnection, you can even use a combination of both. Wireless interconnect has advantages over wired interconnect: With wireless interconnect you can add more alarms without adding expensive wiring and it allows Nest Protect to convey. The power connector plugs into a power input block on the Smoke Alarm. What Is The Interconnect Wire On A Smoke Detector. The alarm shall incorporate an activation switch that can be engaged with the included tool or screwdriver to power on the alarm at startup, and deactivate the alarm at end of alarm life. June 2014 - Received a note from Anthon Pang that interconnected CO sensors use a pulsing signal on the common line to indicate alarm (vs steady signal from smoke sensors). Install the new smoke detector base plate. A hardwired smoke alarm installation involves wiring one of the smoke detectors (closest to the voltage source) to a 120 VAC breaker in the main electric panel or tapping from a 120 V electrical box, wiring it using a 14/2 cable with a black (live), a white (neutral), and a ground wire, as shown by the diagram in Figure 5. You can replace a smoke detector with a combination smoke/CO unit. First alert carbon monoxide alarm, carbon monoxide alarms, carbon monoxide detector, co detectors, CO400B - NU-SET . Yes. Remove the smoke alarm from the mounting bracket and disconnect the power. The OneLink alarms transmit extra digital data wirelessly (e.g. That leaves one free wire inside the detector, a red (or sometimes yellow) wire which purpose is to send a signal to all the other detectors or receive a signal from any of the other detectors connected to it. Adding another light switch to the bathroom. On some units supplied with lithium-powered battery, the battery will last the life of the smoke alarm and cannot be replaced. This creates an entire smoke alarm system to help provide you and your family with an early warning to an emergency. If multiple smoke detectors are being installed, your electrician will run a 3-wire cable (with ground) from the first smoke detector to each subsequent smoke detector. Multiple units can be interconnected with push of one button. Wired linked alarms simply put 9 volts on the extra wire to indicate a trip. Cover must be removed! The smoke detector is designed to easily replace most existing 120-volt hardwired alarms. Fasten the base plate using the existing screws or the new hardware supplied. Simply turn the switch on the back of unit or mount to bracket to activate the alarm. Hardwired interconnection uses the wiring in your home to link AC-powered alarms together. Learning the basics of fire safety is the, P4010DCS-W:Smoke Alarm with Wire-Free Interconnect, P4010LDCS-W:Smoke Alarm with Wire-Free Interconnect and Emergency Safety Light, P4010DCSCO-W:Combination Smoke and CO Alarm with Wire-Free Interconnect, P4010ACS-W:Smoke Alarm with Wire-Free Interconnect, P4010LACS-W:Smoke Alarm with Wire-Free Interconnect and Emergency Safety Light, P4010ACSCO-W:Combination Smoke and CO Alarm with Wire-Free Interconnect, Compatible with Google Home and Alexa.